Golden Solar! Advance Power! Green Life!

MRS Serires Solar Inverter/ Charger
MRS series is enhanced with MPPT solar charger capability up to 80A and configures AGS(Auto Generator Starting), BTS(Battery Temperature Sensor)to greatly improve inverter's reliability.
Key Features
Parameter


● Pure sine wave solar inverter

● 300% surge power

● Smart remote control (RMT)

● Battery temperature sensor (BTS)

● Automatic generator starting (AGS)

● Configurable AC/Solar input priority

● DC start & automatic self-diagnostic function

● Compatible with both linear & non-linear load

● Designed to operate under harsh environment

● Easy to install & easy to operate & easy to solve

● Support solar panel with MPPT function (Optional)  

● Low DC voltage supports home & office appliances

● Powerful charge rate up to 120Amp, selectable from 0%-100%

● High efficiency design & “Power Saving Mode” to conserve energy

● Battery priority mode, designates inverter-preferred UPS configuration

● 13 VDC battery recover point, dedicated for renewable energy systems

● 8 pre-set battery type selector plus de-sulphation for totally flat batteries

● 4-step intelligent battery charging, PFC (power factor correction) for charger

● 8ms typical transfer time between utility & battery, guarantees power continuity

● 15s delay before transfer when AC resumes, protection for load when used with generator




SOPOWER MRS complete solar power system connection.jpg

Model1KW1.5KW2KW3KW4KW5KW6KW8KW10KW12KW15KW18KW
Continuous Output Power1KW1.5KW2KW3KW4KW5KW6KW8KW10KW12KW15KW18KW
Surge Rating(20s)3KW4.5KW6KW9KW12KW15KW18KW24KW30KW36KW45KW54KW
Inverter Output
Output WaveformPure Sine wave / Same as input(Bypass Mode)
Nominal Efficiency>88% (Peak)
Line Mode Efficiency>95%
Power Factor0.9-1.0
Nominal Output Voltage rms100-110-120Vac / 220-230-240Vac
Output Voltage Regulation±10% RMS
Output Frequency50Hz ± 0.3Hz/60Hz ± 0.3Hz
Short Circuit ProtectionYes( 1 sec after fault)
Typical Transfer Time10ms (Max)
THD< 3% (Rated battery level, rated full linear   load)
DC Input
Nominal Input Voltage12V/24V12V/24V/48V24V/48V24V/48V/96V48V/96V
Minimum Start Voltage10.0Vdc   / 10.5Vdc for 12Vdc Mode*2 for 24Vdc, *4 for 48Vdc, *8 for 96Vdc 
Low Battery Alarm10.5Vdc   / 11.0Vdc for 12Vdc Mode
Low Battery Trip10.0Vdc   / 10.5Vdc for 12Vdc Mode
High Voltage Alarm16.0Vdc   for 12Vdc Mode
Low Battery voltage recover15.5Vdc   for 12Vdc Mode
Idle Consumption-Search Mode< 25 W when Power Saver On.(Refer to Table )
AC Charger
Output VoltageDepends on battery type (Refer to Table 2.5.2)
Charger Breaker Rating20A20A20A25A32A40A40A50A80A80A100A125A
Max Charge Power Rate1/3   Rating Power (Refer to Table 2.5.3)

Battery Initial Voltage for Start 10-15.7Vdc   for 12Vdc Mode*2 for 24Vdc, *4 for 48Vdc, *8 for 96Vdc
Over Charge Protection S.D.15.7Vdc   for 12Vdc Mode
Battery Type SelectorSwitching   SettingDescriptionFast   Mode/ VDCFloat Mode/ VDC
0Charger Off
1Gel   USA14.0 13.7
2AGM   1 14.1 13.4
3Lithium13.8 13.6
4Sealed   Lead Acid14.4 13.6
5Gel   EURO14.4 13.8
6Open   Lead AckJ14.8 13.8
7LifePO414.0 13.8
8De-sulphation15.5   (4 hours then off)13.8
9Classic   LFP13.6 13.5
For 12Vdc Mode Series (*2 for   24Vdc Mode;*4 for 48Vdc Mode;*8 for 96Vdc Mode)
BTS
Battery Temperature Sensor(Optional) Yes(Refer to the table ) Variances in   Charging Voltage & S.D Voltage Base on the Battery Temperature.
Bypass & Protection
Input Voltage WaveformSine wave (Grid or Generator)
Nominal Voltage100-110-120Vac/ 220-230-240Vac
Max Input AC Voltage150Vac For 120Vac LV Mode : 300Vac For 230Vac   HV Mode:
Nominal Input Frequency50Hz / 60Hz
Low Freq Trip47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz
High Freq Trip55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz
Overload Protection (SMPS load)Circuit Breaker
Output Short Circuit ProtectionCircuit Breaker
Bypass Breaker Rating20A20A20A25A32A40A40A50A80A80A100A125A
Transfer Switch Rating30Amp   for UL&TUV40Amp   for UL80Amp   for UL100Amp for UL
Bypass without Battery ConnectedYes (optional)
Max Bypass Current30Amp 40Amp80Amp80Amp
Solar Charger (optional)
Rated Voltage12Vdc24Vdc48Vdc
Rated Charge Current (Includes Load Current)40A/60Amp40Amp
Load Current15Amp
Input Voltage Range15-150Vdc30-150Vdc60-150Vdc
Max. PV Open Circuit Array Voltage150Vdc
Overload Protection (DC Load)2.0*I (Rated) >5s; 1.5*I (Rated)   >20s;  1.25*I (Rated)  Temperature Controlled
Typical Idle ConsumptionAt idle < 10mA
Bulk Charge14.6Vdc29.2Vdc58.4Vdc
Floating Charge13.4Vdc26.8Vdc53.6Vdc
Equalization Charge14.0Vdc28.9Vdc58.0Vdc
Over Charge Disconnect14.8Vdc29.6Vdc59.2Vdc
Over Charge Recovery13.6Vdc27.2Vdc54.4Vdc
Over Discharge Disconnect10.8Vdc21.6Vdc43.2Vdc
Over Discharge Reconnect12.4Vdc24.6Vdc49.6Vdc
Temperature Compersation-   13.2mV/℃-   26.4mV/℃- 52.8mV/℃
Lead Acid Battery SettingsAdjustable
NiCad Battery SettingsAdjustable
Low Voltage Reconnect12.0   - 14.0Vdc24.0   - 28.0Vdc48.0 - 56.0Vdc
Low Voltage Disconnect10.5   - 12.5Vdc21.0   - 25.0Vdc42.0 - 50.0Vdc
Ambient Temperature0-40℃ (Full load)  40-60℃ (De-rating)
Weight (KG)2.5
Mechanical Specifications 
MountingWall Mount
DisplayStatus LEDs / Status LEDs+LCD
Inverter Dimensions(L*W*H) mm 388*415*200488*415*200588*415*200688*415*230
Packing Dimensions(L*W*H) mm 550*520*310650*520*310750*520*310850*520*350
N.W. (KGS)212223273848496066707578
G.W. (KGS)242526304151526369737881