Golden Solar! Advance Power! Green Life!
● Efficient
Support over capacity ratio: 1.6X DC input overload.
High energy continuous output: 1.1X AC output overload.
The MPPT efficiency is up to 99.90%.
The lowest starting voltage can reach to 160V.
● Intelligent
Intelligent monitoring: one-stop intelligent operation and maintenance platform for users,
providing comprehensive and intuitive power station data monitoring.
Support RS485 / USB / WiFi / GPRS.
● Reliable
IP66
Anti-islanding protection, Input over current protection, Output over current protection,
DC reverse connection protection, String fault protection, Surge protection,
Insulation resistance detection, AC leakage current detection, PID repair,
Low voltage ride through, Arc fault detection, Night SVG function, etc..
● Flexible
Intelligent IV scanning function: it can accurately locate the fault string and make the operation
and maintenance more efficient.
9~12 MPPT: more flexible string configuration and more choices for installation.
Remote maintenance: support online remote upgrade.
Fan drawer design: 1 minute quick fan replacement.
Model | MTG2-100K | MTG2-110K | MTG2-136K |
Input (DC) | |||
Max. Input Power | 150KW | 150KW | 160KW |
Max. Input Voltage | 1100V | ||
Start Voltage / Min. Operation Voltage | 250/180V | ||
MPPT Voltage Range | 180~1000V | ||
Number of MPP Trackers / String per MPPT | 9/2 | 10/2 | 12/2 |
Max. Current per MPPT | 26A | 26A | 26A |
Output (AC) | |||
Rated Output Power | 100KW | 110KW | 136KW |
Max. Apparent Power | 110KVA | 121KVA | 150KVA |
Rated Output Current | 144.3A | 158.8A | 163.5A |
Max. Output Current | 158.8A | 174.6A | 174.6A |
Rated Grid Frequency | 50Hz / 60Hz | ||
Rated Grid Voltage | 230V/400V, 3L+N+PE / 3L+PE | 277V/480V, 3L+N+PE / 3L+PE | |
Power Factor | - 0.8 ~ +0.8 (adjustable) | ||
THDI | < 3% (at rated power) | ||
Efficiency | |||
Max. Efficiency | 99.00% | ||
Euro. Efficiency | 98.50% | ||
MPPT Efficiency | 99.90% | ||
Protection | |||
Porotection | DC switch, Anti-islanding protection, Input over current proteciton, Output over current protection, DC reverse connection protection, String fault protection, Surge protection, Insulation resistance detection, AC leakage current detection, PID repair, Low voltage ride through, Arc fault detection, Night SVG function, etc. | ||
Communication | |||
Display | LED / LCD / Bluetooth+App | ||
Communication | Standard: RS485 / USB ; Optional: WiFi / DRM / Bluetooth | ||
Standard Compliance | |||
Grid Connection Standards | IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N 4110:2018, VDE-AR-N 4105:2018, VDE-AR-N 4120:2018, EN 50549, AS/NZS 4777.2:2015, CEI 0-21, VDE 0126-1-1/A1 VFR 2014, UTE C15-712-1:2013, DEWA DRRG, NRS 097-2-1, MEA/PEA, C10/11, G98/G99 | ||
Safety / EMC | IEC 62109-1:2010, IEC 62109-2:2011, EN 61000-6-2:2005, EN 61000-6-3:2007/A1:2011 | ||
General Data | |||
Dimension (W*H*D) | 1050*660*330mm | ||
Weight | 95KG | 98KG | 101KG |
Operating Temperature Range | -30~+60℃ (Derating above 45℃) | ||
Cooling Method | Smart cooling | ||
Protection Degree | IP66 | ||
Noise | <70dB | ||
Max. Operating Altitude | 4000m (Derating above 2000m) | ||
Relative Humidity | 0~100% | ||
Consumption at Night | < 1W | ||
Topology | Transformerless | ||
Warranty | 5 years (standard) / 10 years (optional) |